Telluride Country Club

Remodeling of Women’s Spa

This web-page has been produced in order to exhibit the site’s existing conditions, which are reflected in the photos and on the as-built drawings exhibited below.

The purpose of this “project specific” web-page is to provide an example of a one-stop view-ability for all the evolving collaborate efforts.

This framework serves well for organizing and articulating meaning for;

  • a.) The Owner’s Desires

  • b.) The Contractor’s Input for the site practicalities

  • c.) The Designers graphic directions / contributions

This can allow the project to become the beneficiary of a well rounded approach and allow the new prescription being mandated by officials for the requirements to become better understood for under current code compliant applicability.

For the purposes of the evolving discussions, please refer to each of the photos and as-built exhibits below by their assigned number and title in order to allow a common language to be maintained during further communications.

EXISTING SITE PHOTOS:

PRIOR RETROFIT-001 thru 003

Click on image to enlarge photos

PRIOR RETROFIT-001__PRIOR RETROFIT-002__PRIOR RETROFIT-003

REMOVED PARTS-001 thru 002

Click on image to enlarge photos

REMOVED PARTS-001__REMOVED PARTS-002

TEMPORARY STATE UNTIL SPRING-001 THRU 002

Click on image to enlarge photos

REMOVED PARTS-001__TEMPORARY STATE UNTIL SPRING-002

EQUIPMENT LIST KIVA SPA-001

EQUIPMENT LIST KIVA SPA-001

ROOM LAYOUT KIVA SPA-002

ROOM LAYOUT KIVA SPA-002

ELEVATION SECTION A-A KIVA SPA-003

ELEVATION SECTION A-A KIVA SPA-003

ELEVATION SECTION C-C KIVA SPA-004

ELEVATION SECTION C-C KIVA SPA-004

DIMENSIONS KIVA SPA-006

DIMENSIONS KIVA SPA-006

LAYOUT KIVA SPA-007

LAYOUT KIVA SPA-007

ELEVATION SECTION B-B KIVA SPA-008

ELEVATION SECTION B-B KIVA SPA-008

Remodeling Design

SPA SECTION EXAMPLE

Custom In-Ground Spa Section

We proposed the complete demolition of the existing spa and a complete rebuild. In approaching the project in this fashion the latest technologies can be deployed and it can be brought up to current code standards.

The form provided below can allow your to upload additional pdf. and jpg.files, together with providing us with narrative information in a “quick click” single action SUBMIT response.

Request For Information (RFI) Commercial Spa
Maximum upload size: 31.46MB
Please provide an image (jpg.file) that shows the entire property layout.
Maximum upload size: 31.46MB
Please provide an image (jpg.file) with I.D. wall dimensions of the equipment room layout.
Provide us with the best email for which to respond.
Provide us with the best telephone number to make contact, preferable a cell #.
Project's Address:
City
State/Province
Zip/Postal
Country
Provide us with the physical address of the project being considered.
:
Provide us with a written narrative explaining the design work scope intentions. Use the check boxes on this webform below to identify the features.
Indicate the corresponding pool structural engineering requirements.
Please indicate what the pool / spa equipment pad will be provided for it's power requirements.
Please indicate what the pool / spa equipment pad will be provided for it's power requirements.
Please indicate what the pool / spa equipment pad will be provided for it's power requirements.
Indicate the available water source for filling the pool and it's source connection for the daily supply.
Indicate the size of the WPOC
Indicate the static water pressure.
Indicate the wastewater disposal connection type and the type of water contamination expected.
Indicate the sewer connection pipe size.
According to CBC Section 3100, pools that are wider than 40'-0" shall require a Rim-Flow Gutter System. Please use the check box field above in order to better describe the desired approach (when the pool is wider than 40'-0").
According to CBC Section 3100, pools that are narrower than 40'-0" can utilize a Surface Skimmer System. Please use the check box field above in order to better describe the desires in approach (when the pool is narrower than 40'-0").
Sending

Aquatic Mechanical Engineering  (800) 766-5259